www.openmind-tech.com
January 2009
OPEN MIND Technologies AG
___________________________________________________________________
OPEN MIND CAD Interfaces V7.6
English
___________________________________________________________________
1. General Information
The module "OPEN MIND CAD Interfaces" enables the import of 3D CAD-models in several formats and
the conversion into the internal *.e3-Format.
1.1. System requirements:
- thinkdesign 2007.1 / 2008.1 or hyperCAD 2007.1 / 2008.1
- CAM Utilities 9.7
1.2. General:
The following models can be converted - depending on the acquired license - :
-CATIA V4 (file type:*.model, *.exp, up to version 4.2.4)
-CATIA V5 (file type:*.CATpart, up to version R19)
-CATIA V5 (file type:*.CATproduct, up to version R19)
-ProEngineer (file type:*.prt.*, *.asm, from version 18 up to Wildfire 4)
-Unigraphics (file type:*.prt, up to version NX 6)
-Parasolid (file type:*.x_t,...., up to version R19)
-SolidWorks (file type *.sldprt, *.sldasm; up to version 2008)
Attention: License codes of version 6.0 are not valid anymore.
___________________________________________________________________
2. Hints to the installation
Condition:
You need Administrator Rights to install the CAD interfaces.
This is also valid for the License server in case of installing network licenses.
Procedure:
The module "OPEN MIND CAD Interfaces" will be provided as a self extracting exe-file.
After you have downloaded the file "OM_CAD_Interfaces_V7_6.exe", please start the installation
on your system by double clicking this file.
The installation will check, whether there is a supported hyperCAD- or thinkdesign-Version already
on the system and will be cancelled, if this is not the case.
The "OPEN MIND CAD Interfaces" will be provided - depending on the language of the installed
CAD program - in the following languages: "German", "English", "French" and "Italian".
Select the corresponding conversion module out of the list, for which you acquired a license.
Please be aware, that the installation will continue only, if at least one module from the list is selected.
Now, the installation copies all the necessary files into the corresponding hyperCAD directory
of your system.
___________________________________________________________________
3. Registering the licence file via InfoCenter
Execute the program InfoCenter from within the program group
"OPEN MIND - CAM Utilities V9.7".
· choose Load in the list view (CAM licenses),
· choose the *.dat format and confirm with OK,
· finish the following dialogue with Yes, to register your license
Please keep in mind that you have to complete the register card and
sent it to OPEN MIND to
get the needed licence file.
The register card has to contain the number of your dongle.
Please keep in mind that after the installation you have to send an email to OPEN MIND
with your dongle number to request your license file.
Your CAD interfaces should be ready to run now.
Tip for network license users:
An installed version of license server 1.7, which is provided with the new version of CAD interfaces
is a condition for using network licenses.
To install the license server, double click on the file TTF_LicenseServer_V1.7_Update.exe
and follow the instructions of the program.
IMPORTANT:
After the installation, the CAD-Reader license server has to be installed new via InfoCenter (Registry > License Server > CAD Reader > Server)
___________________________________________________________________
4. New features
In version 7.03:
SCR-Number Description
31404 Pro/E: no more double curves
29555 Catia V4: no more double curves
29428 Catia V5: Original layer are used in surface mode
31321 Catia V4 Layer (instead of entities) are hidden in surface mode
27291 Catia V5: surface problem solved
In version 7.04:
Support of thinkdesign 2006.1
In version 7.2
Support of SolidWorks 2007 and Catia V5 R17
SCR-Number Description
33186 Catia V5: All geometries are completely available after converting
33132 Catia V5: All surfaces are completely available after converting
32966 Catia V5: CATIA V5 models (64-Bit) can be opened without any problem in hyperCAD 2005.2.
In version 7.21
Support of thinkdesign 2006.2 / hyperCAD 2006.2
In version 7.22
SCR-Number Description
34175 Support of Catia V5R17 SP4
in version 7.4
Support of CATIA V5 (file type:*.CATproduct / CATproduct up to version R18)
Support of Unigraphics (file type:*.prt, up to version NX, including NX5)
In version 7.5
Support of thinkdesign 2008.1 / hyperCAD 2008.1
Support of Pro/Engineer Wildfire 4
Call-Number Description
6293, 6307,
6315,
6287 Feature Recognition correct (CATIA V5)
In version 7.6
Support of Unigraphics (file type:*.prt up to NX6), Catia V5 R19 and Parasolid (file type:*.x_t, x_b, up to version R19)
6132 Assemblies that contain assembly-feature, can not be read in correctly (see item 5.6 Restrictions)
9144 When saving a converted file, the user can decide, if an existing file name will be overwritten or not.
9738 Problems when importing files in *.prt format (with geometries and features ) are solved.
10031 CAD interfaces 7.6 are now working also in hyperCAD 2007.1
___________________________________________________________________
5. Reading of CAD-models
To use the OPEN MIND CAD Interfaces, please activate the toolbars at first. Choose "Customize > Toolbars"
(right-mouse click in the toolbar) and activate the desired toolbars.
There will be a toolbar consisting of two icons for each selected format
in the thinkdesign /hyperCAD -menu bar, which allows you to control the OPEN MIND CAD Interfaces.
The
,
,
,
,
icons open the file selector to select
the cad-files, you want to convert.
The
icon opens the window for controlling
the conversion.
With the icon
you can set the
workplane on one of the axis systems, that are read out during conversion.
5.1 Conversion options
First specify the conversion-parameters as follows:
Entity Filter

Using these options, you select the entity types to be converted.
When the check-box is activated, all entity types of this category will be converted.
Please be aware, in order to get the best result, all categories will be selected by default
(exception: Datum
planes for ProEngineer).
You can convert Points, Curves, Surfaces,
Solids, Axis systems, Texts and Datum planes.
Note:
The entity filter Datum planes is only available for ProEngineer CAD interface
The entity filter Axis systems is only available for ProEngineer and CATIA V4 CAD interface.
The entity filter Texts is not available for Parasolid CAD interface.
Solid Conversion Mode

Break down solids into surfaces
Solids are separated into single surfaces. The original topology of the Solid is lost.
Collect solid surfaces into layers
All surfaces will be collected into defined layers (on which shouldn't be other entities).
Later, they can be assembled into a solid with a CAD command. Thereby the original layer will be overwrite.
Collect solid surfaces into components
thinkdesign/hyperCAD entities (solid surfaces) were collected into components during conversion.
The name of the elements is used as identification for the generated components. The layer assignment
of the solid surfaces remains.
Create solid
All single surfaces
persist as part of the solid. The topology of the solid persists. Depending on
the settings at the entity conversion mode, a converted solid is composed of
NURBS surfaces,
cylinder surfaces and planes.
Entity Conversion Mode

Convert NOSHOW entities
With this option all covered elements are considered during the conversion and converted accordingly.
Create 3D boundaries
The output format (*.e3) contains 3D boundaries, that will be available explicitly for further work on the
CAD model (e.g. for the contour selection etc..).
Convert all surfaces in NURBS
All analytical surfaces (exception: planes) are converted into NURBS and are available for further usage.
If this option is not activated, in this Version (2.3) cylinder surfaces and planes persist as well as cones,
bullets and toroids are converted into surfaces of revolution.
Note:
The option Convert all surfaces in NURBS is not available in the CATIA V4 CAD interface.
Take over of CAM features in hyperMILL
CAM relevant Feature of a model are converted to CAM features and are taken over to
the hyperMILL feature list. This function is available for CATIA V5 and Pro/Engineer.
Extended
Automatic File Save
The thinkdesign model is automatically saved with the original model name.
NURBS Approximation
Here you define the mathematical accuracy of the NURBS-approximation
Normally the value 0.0001 is sufficient.
Start layer for surfaces

Note: this option is available only if you choose the option Collect surfaces into layers
before. With this option, you define the start layer for the surfaces that have to be converted.
All further surfaces were collected automatically on the next available layer.
Feature
Adjust features to model geometry
The CAM Features, taken over to hyperMILL, are adjusted to the model geometry.
5.2. Selection of the CAD-file
Open the window "Open"
by clicking one of the following icons:
,
,
, ![]()
Select the file and the file type, you want to convert. Click on the button Open, for loading the file or
Cancel for interrupting the loading process.
5.3 Converting process
The converting process creates a report (log)-file from, that has the same name like the converted cad-file
ending with "*.log (<CAD-file>.log), located in the same folder.
Note: Due to there are ambiguous layer assignments in ProE models but no possibility of mapping them
in thinkdesign layers, the layer structure of ProE models is not taken over to thinkdesign.
5.4 Set workplane
To set the workplane on
one of the axis systems that are read out during conversion, click on the icon ![]()
and select the desired axis system from the list.
Note:
to the name of the axis system: the original name is the first part of the current term.
5.5 Mapping table
___________________________________________________________________
|
CATIA V4 Mapping Table in thinkdesign / hyperCAD |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
CATIA V4 ENTITY |
TYP NUMBER |
hyperCAD |
FILTER |
|
|
|
|
|
|
POINT |
1 |
Point |
Point |
|
|
|
|
|
|
LINE |
2 |
Line |
Curve |
|
|
|
|
|
|
CURVE |
3 |
Curve |
Curve |
|
|
|
|
|
|
PLANE |
4 |
Plane |
Surface |
|
|
|
|
|
|
SURFACE |
5 |
Surface |
Surface |
|
|
|
|
|
|
FACE |
6 |
Trimmed Surf |
Surface |
|
|
|
|
|
|
VOLUME |
7 |
Surfaces |
Surface |
|
|
|
|
|
|
3-AXIS SYSTEM |
8 |
ARS |
- |
|
|
|
|
|
|
SKIN |
13 |
Surfaces + Component |
Surface |
|
|
|
|
|
|
POLYHEDRAL SURFACE |
16 |
Planes |
Surface |
|
|
|
|
|
|
POLYHEDRAL SOLID |
17/1 |
Planes/Solid |
Solid |
|
|
|
|
|
|
EXACT SOLID |
17/2 |
Surfaces/Solid |
Solid |
|
|
|
|
|
|
CIRCLE |
20 |
Arc |
Curve |
|
|
|
|
|
|
ELLIPSE |
21 |
Curve |
Curve |
|
|
|
|
|
|
PARABOLA |
22 |
Curve |
Curve |
|
|
|
|
|
|
HYPERBOLA |
23 |
Curve |
Curve |
|
|
|
|
|
|
COMPOSITE CURVE |
24 |
Curves/Lines |
Curve |
|
|
|
|
|
|
SPACE DITTO* |
28 |
Entities |
- |
|
|
|
|
|
|
* DETAILs are resolved |
|
|
|
5.6 Restrictions
Assemblies, which contain Assembly-Feature, cannot be read in correctly, because the geometry,
generated by the Assembly-Feature is not contained within the model geometry.
Such assemblies are no more read in, in the log-file the error message
'Error modified parts in the ASM: *.SLDASM' appears.
Parts/Assemblies, which contain Assembly-Feature, are no longer imported into hyperCAD.
___________________________________________________________________
Headquarter
OPEN MIND Technologies AG
Argelsrieder Feld 5
D-82234 Wessling
Phone:+49 8153 933-500
Fax: +49 8153 933-501
E-Mail:Sales.Europe@openmind-tech.com
OPEN MIND, Hannover
Geschäftsstelle Nord
Karlsruher Straße 18
30880 Laatzen
Tel.: +49 511 37 430-88
Fax: +49 511 37 430-90
E-Mail: Sales.Europe@openmind-tech.com
OPEN MIND, Fulda
Marienküppel 1
36100 Petersberg
Tel.: +49 661 67 937-36
Fax: +49 661 67 937-35
E-Mail: Sales.Europe@openmind-tech.com
OPEN MIND, Dortmund
Brücherhofstraße 60b
44269 Dortmund
Tel.: +49 231 408 09-43
Fax: +49 231 408 09-44
E-Mail: Sales.Europe@openmind-tech.com
OPEN MIND, Stuttgart
Geschäftsstelle West
Monreposstraße 55
71634 Ludwigsburg
Tel.: +49 7141 50 563-34
Fax: +49 7141 50 563-35
E-Mail: Sales.Europe@openmind-tech.com
OPEN MIND, Reutlingen
Schillerstraße 63
72810 Gomaringen
Tel.: +49 7141 50 563-34
Fax: +49 7141 50 563-35
E-Mail: Sales.Europe@openmind-tech.com
OPEN MIND, Würzburg
Obertor 11
97837 Erlenbach
Tel.: +49 7141 50 563-34
Fax: +49 7141 50 563-35
E-Mail: Sales.Europe@openmind-tech.com
OPEN MIND, Füssen
Geschäftsstelle Süd
Abt-Hafner-Straße 7b
87629 Füssen
Tel.: +49 8362 93 06 55-0
Fax: +49 8362 93 06 55-20
E-Mail: Sales.Europe@openmind-tech.com
OPEN MIND, Chiemsee
Greimelstraße 28c
83236 Übersee
Tel.: +49 8642 59 51-50
Fax: +49 8642 59 51-70
E-Mail: Sales.Europe@openmind-tech.com
OPEN MIND, Nürnberg
Am Sportplatz 2
91623 Sachsen bei Ansbach
Tel.: +49 9827 24 03-00
Fax: +49 9827 24 03-01
E-Mail: Sales.Europe@openmind-tech.com
United Kingdom
OPEN MIND Technologies UK Ltd.
John Eccles House
Robert Robinson Avenue
Oxford Science Park
Oxford OX4 4GP
England
Phone: +44 (1865) 338 026
Fax: +44 (1865) 338 100
E-Mail: Sales.UK@openmind-tech.com
Italy
OPEN MIND Technologies Italia S.r.l.
Via Pomè 14
20017 Rho (MI)
Italia
Phone: +39 02 93 16 25 03
Fax: +39 02 93 18 44 29
E-Mail: Sales.Italy@openmind-tech.com
France
OPEN MIND Technologies SARL
Alain Sutter
1, rue du Baron Chouard
BP 50056 Monswiller
67 701 Saverne Cedex
France
Tel : + 33 (0)3 88 03 17 95
Fax : + 33 (0)3 88 03 17 76
E-mail: Sales.France@openmind-tech.com
Switzerland
OPEN MIND Technologies Schweiz GmbH
Hardstr. 20
CH-8303 Bassersdorf
Phone: +49 7021 959507
Fax: +49 7021 959504
E-Mail: Sales.Switzerland@openmind-tech.com
USA
OPEN MIND Software Technologies, Inc.
70 Walnut Street
Wellesley Hills, MA 02481
USA
Phone: +1 781-239 8095
Fax: +1 270-912 5822
e-mail:Sales.Americas@openmind-tech.com
Singapore
OPEN MIND Technologies Asia Pacific Pte Ltd
10 Ubi Crescent, #05-22
Ubi Techpark
Singapore 408564
Phone: +65 6742-95 56
Fax: +65 6742-95 26
e-mail:Sales.Asia@openmind-tech.com
Japan
OPEN MIND Technologies Japan Inc.
KS Building 1-31-11, Kichijojihoncho
Musashino-shi, Tokyo 180-0004
Japan
Phone: +81 422-23-5305
Fax: +81 422-23-5307
E-Mail: Sales.Japan@openmind-tech.com
India
OPEN MIND Technologies India
1109 ,11th floor, Barton Center
#84, M.G. Road
Bangalore 560001
India
Phone: 00 91 80 30504647
Fax: 00 91 80 30505554
E-Mail : sales.india@openmind-tech.com
Taiwan
OPEN MIND Technologies Taiwan
3F, No.153, Hwan-Pei Road.,
Chungli City 320, Taiwan, R.O.C.
Phone: 00 886 3 4613125
Fax: 00 886 3 4613156
E-Mail:sales.taiwan@openmind-tech.com
China
OPEN MIND Technologies China Co. Ltd
Suite 1507, Le Kai Tower
660 Shang Cheng Road
Shanghai 200120
China
Phone: 00 86 21 5887 6572
Fax: 00 86 21 5887 6573
E-Mail: sales.china@openmind-tech.com